A communication cable consists of two symmetrically arranged conductors forming a communication loop. There are two types: high-frequency and low-frequency. The former has a maximum transmission frequency of up to 800 kHz, corresponding to 180 telephone lines in one loop; the latter typically has a maximum transmission frequency of less than 252 kHz, equivalent to 60 telephone lines in one loop. The electromagnetic field of a symmetrical communication cable is open (Figure 4). At high frequencies, the loop attenuation and loss are significant, and there is considerable interference between loops and from external sources, making it difficult to increase transmission frequency and capacity.
Long-distance symmetrical communication cables consist of four-wire groups with varying numbers and insulation structures. The most common form of four-wire group is a star-stranded group, although some use a double-twisted pair. Insulation methods include paper tape insulation, paper-rope (paper tape and paper rope) insulation, polyethylene rope-tape insulation, polystyrene rope-tape insulation, and foamed polyethylene insulation, among others. High-frequency long-distance symmetrical communication cables have high transmission frequencies, so the structural performance requirements for the cable are high. A star-stranded four-wire group structure with rope-rope insulation is generally used. Polystyrene and polyethylene are commonly used insulation materials. Paper tape and paper rope insulation are generally used in low-frequency symmetrical communication cables below 252 kHz.