Cat6A STP Ethernet Cable

Cat6A STP Ethernet Cable

Four pairs of 23 or 22 AWG copper in PE insulation twist at optimized lays to cut high-frequency crosstalk; a cross-web or spacer steadies the pairs. Each pair gets its own longitudinal foil plus a drain wire, then an overall tinned-copper braid after cabling, density designed to EMC, with a separation tape between pair and overall screens and reliable drain contact. A separation tape and a PVC or LSZH jacket printed with CAT6A, SFTP, AWG, meter marks, and batch follow. The double screen suppresses both high- and low-frequency noise more fully but costs more and flexes less than FTP; handle pair screens, overall screen, and drain wires separately at termination.
Send Inquiry
Description
Technical Parameters

Guangzhou Yuedao Industrial Co., Ltd. is one of the leading manufacturers and suppliers of cat6a stp ethernet cable in China. We are committed to providing high quality customized products with competitive price. Welcome to buy high-grade cat6a stp ethernet cable in stock here from our factory. Also, free sample is available.

 

Cat6A STP Ethernet Cable Construction

Four pairs of 23 or 22 AWG copper in PE insulation twist at optimized lays to cut high-frequency crosstalk; a cross-web or spacer steadies the pairs. Each pair gets its own longitudinal foil plus a drain wire, then an overall tinned-copper braid after cabling, density designed to EMC, with a separation tape between pair and overall screens and reliable drain contact. A separation tape and a PVC or LSZH jacket printed with CAT6A, SFTP, AWG, meter marks, and batch follow. The double screen suppresses both high- and low-frequency noise more fully but costs more and flexes less than FTP; handle pair screens, overall screen, and drain wires separately at termination.

 

Cat6A STP Ethernet Cable Technical Data

Parameter

Specification / Value

Characteristic Impedance

100 Ω @ 500 MHz

Data Rate

10 Gbps; PoE

Operating Temperature

−20 to 70 °C

Min. Bend Radius (fixed)

≥ 8 × OD

Flame Retardancy

IEC 60332-1; LSZH option

Quality Checks

Pair & overall shield continuity, drain wire

 

Cat6A STP Ethernet Cable Application

Aimed at indoor scenarios demanding high EMC and ample 10-Gigabit headroom-data-center core links, financial rooms, medical-imaging and operating-room networks, industrial-office hybrids, precision laboratory instruments, security-monitoring centers, data points near VFD gear, and weak-current riser backbones. SFTP combines pair foil with a tinned-copper overall braid; CAT6A offers 500 MHz and 10 Gbps in fixed runs through trays, trunking, and conduits. It is not for continuous chain motion, outdoor burial, or prolonged oily conditions.